VISION 8000 EI60 Series Fire Rated

Profab Access

Profab Access’ VISION 8000 EI60 Series range of fire rated riser doors provides access into tiled jointless plaster and plasterboard walls where access to mechanical and electrical services is required. Specified in commercial, residential and public buildings, the riser doors are supplied with a metal door tray lined with tile backing board, so the chosen cladding can be applied on site delivering the highest standards in fire safety, security and practicality with a visually impacting finish. *A small scale test may be required to ensure legal compliance.

FEATURES / BENEFITS

COMPOSITION

The welded metal frame holds a metal door tray lined with tile backing board. The door is hinged via fully adjustable concealed hinges and opens out towards the user. It is held closed by either a three point lock (3PL) or a three point high security lock (3HS).

  • Fire rated up to 60 minutes for integrity and insulation (EI60 Specification)
  • Visually impacting within an overall design
  • Façade of the riser door can be clad in potentially combustible materials including timber or laminated timber
  • Concealed for a seamless aesthetic finish
  • Maximum cladding build depth of 25 mm
  • Easy to install and lockable
  • Single door (SD) or double door (DD) configurations
  • High performance range, for vertical use with frame and lock options
  • Fully recyclable at end of life

Panels are designed to take potentially combustible cladding materials, subject to assessment or small scale testing to ensure legal compliance.

A simple yet secure means of accessing building services through clad walls without affecting the design aesthetic.

Supplied fully powder coated in matt RAL 9010, with other colours available on request.

Please contact our Technical team on 01827 719051 for more information.


FRAME

1.5 mm thick, factory welded electro-galvanised mild steel with concealed frame flange.

  • Factory welded frame to specific sizes
  • Powder coat finish matt RAL 9010M as standard


DOOR

1.2 mm thick, electro-galvanised mild steel door tray

  • Maximum build up of cladding is 25 mm
  • Concealed load bearing hinges with up to 120kg capacity
  • Rubber gasket around all sides
  • A constant gap is maintained between the door and the frame
  • Lined with tile backing: 12 mm glass reinforced gypsum board
  • Powder coat finish to matt RAL 9010M as standard
  • The door opens towards the user
  • The door is removable if damage occurs or during installation
  • Single door (SD) and double door (DD) configurations.

 

LOCKS

Available with;

  • 3 point lock (3PL)
  • 3 point high security lock (3HS)


FIRE RATING

THE VISION 8000 EI60 SERIES FIRE RATED riser door is fire rated for up to 60 minutes for integrity and insulation – tested to BS EN 1634-1:2000

  • EI60 specification

It is designed to not impair the resistance of the rated wall it is installed to.


TYPICAL SIZES / WEIGHTS 

Our VISION 8000 EI60 Series fire rated riser doors are made to order and are designed to be clad to match the surrounding décor scheme. They are available in sizes up to 975 mm (w) x 2390 mm (h) maximum for a single door (SD). Size refers to outer frame size.

Our technical team who will assist you to determine the correct specification and dimensions for your project. 

MAX SIZES

Leaf width (maximum) = 975 mm
Leaf height (maximum) = 2390 mm


NOTES

  • All doors hinge along dimension Y
  • Air permeability test (pending)

Specifications

Fire Rating
Fire Rated for 1hr (1FR) for integrity and insulation - tested to BS EN 1634-1:2000
Suitability/use
Suitable for vertical use where riser door is to be installed prior to cladding. Ideal for use in commercial, residential and public buildings. Manufactured to order and designed to take potentially combustible cladding materials, subject to assessment or small scale testing A small scale test may be required to ensure legal compliance.
Material(s)
Frame 1.5 mm / Door 1.2 mm thick electro-galvanised mild steel. Door lined with 12mm glass reinforced gypsum board.
Finish/effect/texture
White powder coated frame and door to RAL 9010M (Matt finish)