Hueck Trigon

Hueck UK

Elevation width

  • Elevation width of transom and cover profiles 60 mm

Profile depth

  • In accordance with static requirements between 32 and 194 mm

Insulating zone

  • Insulating profiles made of glass fibre-reinforced polypropylene
  • Foamed spacer profiles for increased thermal insulation

Gaskets

  • Vulcanised shaped gasket pieces covering the entire joint area are used in the transom connection area

Test results

  • Uf = 0.88 – 1.5 W/m2K
  • Water tightness RE1200 (EN 12154)
  • Air permeability 4A (EN 12152)
  • Resistance to wind load 2400 / 3600 Pa (EN 13116)
  • Impact resistance I5 / E5 (EN 14 019)
  • Sound reduction Rw,P bis 45 dB (EN ISO 140 - 3)
  • Burglar resistance WK2, WK3 (ENV 1627)
  • System test "Crash-safe glazing in accordance with TRAV"
  • European approval ETA-13/0675
Find products