Angled Standing Seam Zinc Cladding, what you should know

14 May 2015
News

Following the successful completion of the Bolton College STEM Centre with its beautiful angled seams, Simon Walker, Category Manager for SIG Zinc & Copper has interviewed Lee Smith, contracts manager for Longworth Building Services, about the key things to consider when looking at specifying this kind of cladding. Here are his top tips for a successful project.

Consider the Substrate and get your Details Right

As with all metal cladding, the most important basic rule is to ensure that your choice of substrate, roof build up and detailing complies with manufacturers recommendations. Is the substrate suitable for the product? If not there may be a risk of catastrophic failure.

Different areas of your project may also require different substrates, a pool area for example, where there are high levels of humidity. Whilst there are standard details available, in order to ensure you are protected, you should not simply rely on these but consult your supplier and manufacturer for their advice and detailing, making sure it is up to date. A good supplier will provide you with good quality design support for free, and provide commensurate guarantees.

Decide which direction you want the Angled Seams

Standing seams are asymmetrical, so consider the direction of your standing seams before you work out the detail of the cladding. Otherwise water running off the cladding will run into the seam (the undercloak) rather than over the seam (the overcloak).

Vertical Zinc Cladding Seams are different than Roofing Seams

The way vertical cladding seams are finished are different to roofing seams. Roofing standing seams will be double lock whilst on cladding they will be single lock. As a result there is a slightly different aesthetic effect, which you might want to consider in your design.

Make sure your client is aware of Oilcanning effect

Standing seam metal cladding is thin, and in the process of rolling the coil through a machine, a certain amount of ripple or ‘quilting’ is inevitable. This quality is often very popular with some architects and clients, but others won’t want it. You can reduce (but not completely remove) the oilcanning effect by reducing the seam centres. Normal standing seams will be at 500-600mm, but on Bolton College STEM Centre the centres were reduced to 425mm.

Metal cladding is a specialist skill, requiring skilled installers, skilled designers and proper choices in terms of substrate, detailing and installation.

SIG Design & Technology takes the risk out of roof design, offering a genuinely independent choice of waterproofing for flat, green, zinc and copper roofs. Designs are covered by our PI insurance and we’re part of SIG plc, a FTSE250 company. Our blog at www.singleply.co.uk/blog explores some of your common problems in roof design and system choice, or book our new RIBA CPDs, ‘A Structured Approach to Roof Specification & Design’ and ‘Specifying Hard Metals: Choosing the Right Product for the Project’.